Specifications
- Float switch for water novel control.
- It has 2 m cable with rubber cover and contrAdjustment point.
- Supply voltage: 230 VAC. Maximum current: 16 A (resistive) and 4 A (inductive)
- Degree of protection IP68 to water and humidity.
Watch video
PVP
€15.95
Price including VAT:
€15.95
PVD
€12.89
PVP: Retail price.
Check conditions.
PVP: Sale price to distributors.
Check conditions.
2 years
warranty
warranty
14 days
returns
returns
100%
safe
safe
Specifications
- Float switch for water novel control.
- It has 2 m cable with rubber cover and contrAdjustment point.
- Supply voltage: 230 VAC. Maximum current: 16 A (resistive) and 4 A (inductive)
- Degree of protection IP68 to water and humidity.
Keywords
Did not find what you were looking for? These topic could help you
More info
Float switch for the control of maximum or minimum levels of water or liquids in general. System that provides a signal when the water level falls or exceeds a defined value. Ideal to be used in the process of filling or emptying water tanks.
Specifications
Specifications
- Float switch for water novel control.
- It has 2 m cable with rubber cover and contrAdjustment point.
- Supply voltage: 230 VAC. Maximum current: 16 A (resistive) and 4 A (inductive)
- Degree of protection IP68 to water and humidity.
- Gross Weight: 630 g
- Product size (width x depth x height): 22.0 x 11.0 x 8.0 cm
- Number of packages: 1
- Packages size: 22.0 x 11.0 x 8.0 cm
- Master-pack: 1
Technical terms
- IP Protection
- VAC
IP Protection
hen we talk about IP code (International Protection) we talk about an international standard (IEC 60529) which classifies the protection against external factors, solid or liquid, that has a component or electronic device; LED strips, controllers, meters, security cameras, etc.
This alpha-numerically standard has been designed to sort different levels of protection. Nomenclature starts with IP followed by two numeric values.
- Example IP68:
The first value ranges from 0 to 6 and indicates the protection against solid agents. In this case, strong protection against dust.
The second value is between 0 and 8 and indicates the protection against liquid agents. In this case the complete and prolonged immersion during the time specified by the manufacturer.
We could say that the larger the number is greater IP protection has a device.
In below table, we can see different IP protections levels available.
This alpha-numerically standard has been designed to sort different levels of protection. Nomenclature starts with IP followed by two numeric values.
- Example IP68:
The first value ranges from 0 to 6 and indicates the protection against solid agents. In this case, strong protection against dust.
The second value is between 0 and 8 and indicates the protection against liquid agents. In this case the complete and prolonged immersion during the time specified by the manufacturer.
We could say that the larger the number is greater IP protection has a device.
In below table, we can see different IP protections levels available.
IPXX | First digit (IPxx) | Second digit (IPxx) |
0 | Unprotected. | Unprotected. |
1 | Protection against objects of> 50 mm diameter. | Protection against vertically dripping water. |
2 | Protection against objects of> 12.5 mm diameter. | Protection against inclined drip water up to 15°. |
3 | Protection against objects of> 2 mm in diameter. | Protection against water projected from any direction, up to 60°. |
4 | Protection against objects of> 1 mm in diameter. | Protection against splashing water any direction. |
5 | Ingress of dust is not entirely revented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment . | Protection against water jets. |
6 | Dust tight. | Protection against strong jets of water. |
7 | Protection against complete immersion up to 1 meter for 30 minutes. | |
8 | Protection against complete and prolonged immersion. |